Whole House Generator: Sizing, Fuel, Transfer Switches and Cost
Spring snowstorms that snap tree limbs, summer wind events, and utility shutoffs during high fire danger have made backup power a regular topic among Colorado homeowners. A permanently installed standby unit that starts on its own when the grid goes down is the most convenient option, but it is also a significant project involving the electrical service, a fuel supply, a concrete or composite pad, permits and ongoing maintenance. Buyers also encounter existing generators on listings and need to know what to check. This guide explains how a whole house generator differs from a portable unit, how to size one by the loads that actually matter, the trade-offs between natural gas and propane, how automatic transfer switches and the electrical panel fit in, where the unit can safely go, what permits and maintenance involve, and the cost ranges to plan around.
Part of our Home Electrical guide — start there for the full picture →
Electrical problem? Talk to a licensed electrician.
📞 Call (877) 560-2714What a Whole House Generator Is
A whole house generator, usually called a home standby generator, is an engine-driven generator permanently installed outside the home, connected to the electrical system through a transfer switch and to a permanent fuel supply. When utility power fails, the transfer switch senses the outage, signals the generator to start, and switches the house circuits from utility to generator power, typically within seconds. When utility power returns, the switch transfers back and the generator runs briefly to cool down before shutting off.
Despite the name, not every “whole house” generator powers every circuit at once. Many installations cover selected circuits or use load management to keep large appliances from running simultaneously. The term generally describes an automatic, permanently installed system rather than a guarantee that every load in the house can run together.
Standby vs Portable Generators
Portable generators and standby generators solve the same problem in different ways.
Portable generators
- Lower purchase price and no permanent installation for the generator itself.
- Must be wheeled out, fueled (usually with gasoline, sometimes propane), started and connected during each outage.
- Typically lower output, enough for a refrigerator, sump pump, lights and a few circuits.
- Should connect to the house only through a properly installed transfer switch or interlock with an inlet, never by back-feeding through a dryer outlet with a double-male cord.
- Carry a well-documented carbon monoxide risk when run in garages, basements or near open windows.
Standby generators
- Start automatically, even when the house is empty, which protects against frozen pipes and flooded basements during winter outages.
- Run on natural gas or propane, so there is no gasoline to store or refill.
- Offer higher capacity and can carry central air conditioning, electric ranges or well pumps when sized for them.
- Cost substantially more to buy and install, require permits, and need routine service.
Homeowners who mainly want to protect the refrigerator and keep the furnace blower running during short outages are often well served by a portable generator with a properly installed transfer switch. Households with medical equipment, home offices, sump pumps that must not stop, or frequent extended outages tend to lean toward standby systems.
Battery backup as an alternative
Home battery systems, often paired with rooftop solar, are a third option some Front Range homeowners consider. They run silently, produce no exhaust, and switch over automatically, but their runtime depends on stored energy and how much solar production is available during an outage. Short outages and essential loads suit batteries well; multi-day winter outages with heavy heating loads are more challenging. Some households combine a battery with a smaller generator. Battery systems carry their own electrical, permitting and fire-code considerations, so the same licensed-electrician rule applies.
Best Whole House Generators: our top 3 picks
| Product | Best for | Key features | Price | Buy |
|---|---|---|---|---|
| Generac 22kW + 200A ATS | Best overall for most homes |
| $7,229.00as of Nov 19, 2026 10:24 am GMT+0000 | Buy now →Check current price |
| Generac 14kW + 200A ATS | Mid-size homes, gas furnace |
| $5,839.00as of Nov 19, 2026 10:24 am GMT+0000 | Buy now →Check current price |
| Generac 10kW + 16-circuit ATS | Essential circuits only |
| $4,329.00as of Nov 19, 2026 10:24 am GMT+0000 | Buy now →Check current price |
Prices are Amazon’s listed prices as of the time shown and change often; check Amazon for today’s price. As an Amazon Associate we earn from qualifying purchases.
Sizing a Generator by Your Loads
Generator size is expressed in kilowatts (kW). Undersizing leads to overloads and voltage dips when large motors start; oversizing wastes money and can leave the engine lightly loaded most of the time. Proper sizing starts with a load list rather than the size of the electrical service.
A practical sizing process looks like this:
- List essential loads. Furnace blower and controls, refrigerator and freezer, sump pump, well pump if present, lighting, internet and electronics, garage door opener, and medical devices.
- Add comfort loads. Central air conditioning or heat pump, electric range, electric water heater, electric dryer, and any electric vehicle charger.
- Account for starting surges. Motors on air conditioners, well pumps and sump pumps draw a short burst of current when they start, often several times their running current. The generator must handle the largest motor starting while other loads are running.
- Decide on load management. Many transfer switches and generator controllers can shed large loads, such as the air conditioner or EV charger, when the generator is near capacity, allowing a smaller unit to cover more of the house.
Air-cooled standby units commonly cover the range many single-family homes need for essential and moderate comfort loads, while larger liquid-cooled units serve big homes and all-electric houses. A licensed electrician or generator dealer should perform a load calculation; many will also review a year of utility data or install a temporary meter to understand peak demand.
All-electric homes with heat pumps, electric water heaters and induction ranges need particular care. A cold-climate heat pump with electric backup heat strips can draw a large amount of power during a winter outage, and sizing for that scenario changes the answer considerably.
Natural Gas vs Propane
Most standby generators are dual-fuel capable and can be configured for either natural gas or liquid propane (LP).
Natural gas
Homes with utility gas service in the Denver metro, Boulder, Fort Collins and Colorado Springs typically connect the generator to the existing gas supply. The advantages are an unlimited fuel supply during most outages and no tank to monitor. The catch is capacity: the gas meter and piping must deliver enough volume to run the generator at full load while the furnace and water heater are also firing. Some installations need a larger meter from the utility or a new, larger gas line from the meter to the generator. The guide to gas line installation cost explains what drives that part of the price.
Propane
Rural and foothill homes without gas service usually run standby generators on propane from a leased or owned tank. Propane delivers somewhat more output per unit of fuel than natural gas in many generator ratings, but runtime is limited by tank size, and the tank must be refilled after long outages. Very cold temperatures can also reduce vaporization from smaller tanks. Generator manufacturers and propane suppliers can estimate runtime at various loads.
Altitude matters for both fuels. Engines lose power as elevation rises because the air is thinner, and generator manufacturers publish derating guidance for high-altitude installations. At Front Range and mountain elevations, the usable output can be noticeably lower than the sea-level rating on the brochure, which should be factored into sizing.
Automatic Transfer Switches, the Panel and the Service
The transfer switch is what makes a standby generator safe and automatic. It isolates the home from the utility grid while the generator runs, preventing back-feed onto utility lines that could injure line workers, and it prevents the generator from being connected to the grid when power returns. The guide to the generator transfer switch covers manual and automatic types, interlocks, and how each connects.
Automatic transfer switches come in two broad configurations:
- Service-rated whole-house switches installed between the meter and the main panel. These transfer the entire electrical service and often include the main disconnect for the home. Many whole-house installations use this approach, sometimes paired with load-shedding modules.
- Load-center or sub-panel switches that transfer only selected circuits, which are moved to a dedicated essential-loads panel.
Installation can affect several pieces of service equipment. The electrician may need to relocate or replace the main breaker, add a disconnect, or modify the meter base area, which usually requires coordination with the utility. Older panels with no available spaces, obsolete breaker brands or damaged busbars may need replacement first; the guide to an electrical panel upgrade explains when that becomes part of the scope. Grounding and bonding must also be configured correctly for the type of transfer switch used.
Placement, Clearances and Carbon Monoxide
Every engine-driven generator produces carbon monoxide. Federal safety guidance focuses heavily on portable units because of their history of indoor and garage use, but the same physics apply to standby generators parked near a house.
The CPSC states that more than 200 people in the United States die every year from accidental non-fire CO poisoning associated with consumer products, with more than 100 of those deaths linked to portable generators. CPSC advises never using portable generators inside homes or garages, even with doors and windows open, and running them outside at least 20 feet from the home with the exhaust directed away. The CDC similarly advises keeping generators outdoors more than 20 feet from windows, doors and vents and using battery-powered or battery-backup CO detectors when a generator is in use. The EPA warns that deadly CO levels can build up quickly in garages, crawlspaces and sheds and linger even after the generator shuts off.
Standby generators are designed for outdoor installation closer to the house, but they still have placement rules set by the manufacturer’s installation manual, local codes and fire standards. Those typically address:
- Minimum distance from windows, doors, soffit vents, fresh-air intakes and other openings.
- Distance from combustible walls and overhangs, and clearance for service access.
- Distance from property lines, gas meters, and air conditioner condensers.
- A level, stable pad above expected snow and drainage, with the exhaust side clear.
In practice, homeowners should keep the area around the unit free of snowdrifts, firewood, trash cans and vegetation, and confirm CO alarms are installed on every level and outside sleeping areas, consistent with CPSC recommendations. The guide to the best carbon monoxide detector covers alarm options.
Permits, Noise Rules and HOAs
In most Front Range jurisdictions, a standby generator installation involves an electrical permit and often a mechanical or plumbing permit for the gas connection, with inspections before the system is placed in service. Some cities and counties also apply zoning setbacks or noise limits that affect where the unit can go, particularly in tight lots and townhome communities. Rules differ by municipality, so the contractor should confirm local requirements before ordering equipment.
HOAs commonly regulate visible exterior equipment and may require approval, screening or specific locations. Neighbors may also care about weekly exercise runs. Many modern units allow the exercise cycle to be scheduled at a convenient time and run at reduced speed to lower noise.
Maintenance and Exercise Cycles
A standby generator can sit idle for months, so automatic self-tests are built in. Most units run a short exercise cycle on a set schedule, often weekly or every other week, to keep the engine lubricated, charge the starting battery and confirm the system will start.
Routine maintenance generally includes:
- Oil and filter changes at the intervals in the owner’s manual, plus after extended outage runtime.
- Air filter and spark plug replacement.
- Starting battery testing and periodic replacement.
- Inspecting the enclosure for rodent nests, debris and corrosion.
- Checking the controller for error codes and confirming the transfer switch operates.
- For propane systems, monitoring tank levels before storm season.
Many dealers offer annual service plans. When buying a home with an existing generator, ask for the model, installation date, permit records and service history, and run the test function with the seller present if possible.
What a Home Inspection Covers
The ASHI Standard of Practice requires inspectors to inspect service equipment, main disconnects, panels and overcurrent protection devices, and to describe the location of the main disconnect and subpanels. The standard also says inspectors are not required to inspect ancillary wiring systems and components that are not part of the primary electrical power distribution system, and many inspectors treat a standby generator and its controls as falling outside the standard scope. A home inspector may note the presence of a generator and transfer switch, visible defects and obvious clearance concerns, then recommend that a qualified generator technician evaluate operation, load capacity and maintenance status.
Whole House Generator Costs
Pricing varies with brand, capacity, fuel, transfer switch type, distance from the panel and gas meter, and local permit fees. Rough planning ranges only:
- Portable generator plus inlet and interlock or manual transfer switch: often in the low thousands of dollars total.
- Air-cooled standby generator, installed: commonly in the high four figures to the mid five figures depending on capacity and site work.
- Larger liquid-cooled standby units: substantially more.
- Add-ons: gas meter upgrades, new gas lines, panel replacement, propane tanks, pads, load-management modules and long trenching runs can each add hundreds to thousands of dollars.
- Annual maintenance: typically a few hundred dollars for a dealer service visit, more with repairs.
Comparing quotes is easier when each contractor lists the generator model and altitude-adjusted output, the transfer switch type, which loads are covered, gas or propane work, panel changes, permits and the warranty terms.
A few questions help separate thorough quotes from quick ones:
- Was a load calculation performed, and which loads will the generator carry at the same time?
- Does the quoted size account for altitude derating at this address?
- Will the gas utility need to upgrade the meter, and who coordinates that?
- Who pulls the permits, and is the final inspection included?
- What does the warranty cover, and does it depend on dealer maintenance?
When to Call a Professional
Generator selection, transfer switch wiring and gas connections all belong to licensed professionals: an electrician for the electrical work, a licensed gas fitter or plumber for fuel piping, and a factory-authorized dealer for setup and warranty registration. Buyers evaluating a home with an existing system can use the hiring a home inspector guide and the electrical inspection hub to plan which specialists to include.
More Questions About Whole House Generators
How long can a whole house generator run continuously?
A whole house standby generator connected to natural gas can run for many days continuously as long as the gas supply holds, while a propane unit runs until its tank is empty. Most manufacturers recommend checking oil and the unit after about 24 hours of continuous run time, and extended outages may require an oil change. Propane run time depends on tank size and load; a large tank may last several days at partial load. Homeowners expecting long outages should plan for fuel deliveries and maintenance stops.
How loud is a whole house generator?
A whole house standby generator is typically about as loud as a running air conditioner condenser or a busy conversation, often in the range of 60 to 70 decibels at a short distance. Air-cooled units are generally louder than larger liquid-cooled models, and weekly exercise cycles are often quieter than full-load operation. Sound enclosures and placement away from bedrooms and neighbors’ windows help. Some cities and homeowner associations limit generator noise or exercise hours, so local rules should be checked before installation.
How long does a whole house generator last?
A well-maintained whole house standby generator typically lasts about 20 to 30 years, or a set number of operating hours that varies by engine design. Air-cooled residential units often have a shorter rated engine life than liquid-cooled units. Lifespan depends on regular maintenance: annual oil and filter changes, spark plugs, battery replacement every few years, and keeping the enclosure free of debris and pests. Units in coastal salt air or extreme climates may wear faster without corrosion protection and regular service.
Can a whole house generator power central air conditioning?
Yes, a properly sized whole house generator can power central air conditioning, but the AC compressor’s starting surge must be accounted for. Air conditioners draw a high current for a moment when they start, which can overload an undersized generator. Electricians often add a soft-start kit to the AC or use load management modules that stagger large appliances. A load calculation by a licensed electrician determines whether AC, electric ranges, dryers and well pumps can all run together or need to be managed.
References
- Carbon Monoxide Information Center — U.S. Consumer Product Safety Commission
- Carbon Monoxide Poisoning Basics — Centers for Disease Control and Prevention
- Carbon Monoxide’s Impact on Indoor Air Quality — U.S. Environmental Protection Agency
- ASHI Standard of Practice for Home Inspections — American Society of Home Inspectors
Frequently asked questions
What size whole house generator does a home need?
It depends on the loads you want to run, especially large motors like air conditioners and well pumps, and whether load management is used. A licensed electrician or generator dealer should perform a load calculation and account for altitude derating at Colorado elevations.
Is natural gas or propane better for a standby generator?
Natural gas offers continuous supply where utility service exists, but the meter and piping must have enough capacity. Propane works where gas service is unavailable, with runtime limited by tank size and refills.
How far should a generator be from the house?
For portable generators, CPSC and CDC advise running them outdoors at least 20 feet from the home, away from windows, doors and vents. Standby generators follow the manufacturer's installation clearances and local code requirements.
Is a transfer switch required for a generator?
Yes. A transfer switch or approved interlock isolates the home from the utility grid, preventing dangerous back-feed onto power lines. Standby generators use automatic transfer switches that switch over without manual steps.
How much does a whole house generator cost?
Installed air-cooled standby generators commonly range from the high four figures to the mid five figures, depending on capacity, fuel and electrical work. Gas line upgrades, panel changes and permits can add more.
Does a whole house generator start automatically?
Yes, a standby whole house generator with an automatic transfer switch starts automatically within seconds of a power outage and switches the home to generator power. When utility power returns, the transfer switch moves the home back and the generator shuts down after a cool-down period.
Does a whole house generator increase home value?
A whole house generator can add buyer appeal and some resale value, especially in areas with frequent outages from storms or wildfire power shutoffs. It rarely returns its full cost at sale. A permitted, well-maintained unit with service records is valued more by buyers and inspectors.
Is a whole house generator safe in a flood zone?
A whole house generator can be installed in a flood zone, but it should sit on a raised pad above the expected flood elevation. Floodwater can ruin the engine, controls and wiring. Local code and flood rules may set minimum elevation heights, so the installer should confirm them.
Buying a home that already has a standby generator, or weighing whether to add one? Get in touch here and we can connect you with a Front Range inspector who will review the panel, transfer switch and placement and point out what a generator specialist should verify.