Searching for pictures of radon mitigation systems is how many homeowners first try to make sense of the white pipe running up the side of a house or through a basement. Knowing what each visible component should look like — and where it should be — helps you identify a system at a glance, evaluate whether an existing one was installed correctly, and spot the warning signs of a system that has failed. This guide summarizes EPA and Colorado health-department guidance current as of 2026; consult a certified radon professional for system decisions and your physician for any health concerns.
Part of our Radon Mitigation Systems guide — start there for the full picture →
What a Radon Mitigation System Looks Like
The most common system, active sub-slab depressurization, is recognizable by a continuous run of white PVC pipe, usually 3 or 4 inches in diameter. The pipe begins at a suction point in the lowest level — penetrating the basement slab or a crawl space membrane — runs upward through the home or along an exterior wall, passes through an in-line fan, and discharges above the roofline. A small clear gauge called a manometer is mounted on the pipe in the living area.
In pictures, the giveaway is that vertical white pipe terminating above the roof with no other plumbing purpose, paired with a cylindrical fan housing somewhere along its length. The system runs continuously and is nearly silent when healthy. Our explainer on how radon mitigation systems work walks through how these parts function together, and the parent radon testing guide covers when a system is needed.
The Key Components to Recognize
Each visible part has a job, and learning to spot them turns a confusing pipe into a readable system.
The suction point and pipe
At the base, the pipe enters a sealed suction point cut into the slab or membrane. The PVC should be solidly supported, properly pitched so condensation drains back down, and sealed where it penetrates the floor. Sloppy sealing or unsupported pipe runs are signs of a rushed job.
The fan
The fan is a cylindrical housing spliced into the pipe, located outside the living space — outdoors, in an attic, or in a garage, never in a basement or other occupied area, so any leak from the fan housing does not vent radon back inside. EPA guidance and standard practice require this placement.
The manometer and the vent discharge
The manometer is the U-shaped tube with colored liquid mounted on the pipe; unequal liquid levels show the fan is pulling suction. The vent discharge exits above the roof eave, a set distance above the roof surface and away from windows and other openings to prevent the gas from re-entering.
How to Tell a Quality Install From a Poor One
Pictures reveal a lot about installation quality. A quality job shows clean, well-supported pipe with proper pitch, thorough sealing at the suction point and floor cracks, the fan correctly located outside living space, a manometer reading active suction, and a vent terminating above the roofline well clear of windows.
Red flags are equally visible: a fan installed in a basement, a vent that discharges at ground level or near a window, sagging or unsealed pipe, a missing manometer, or a gauge reading level (no suction). A system that looks complete but reads no suction is not protecting anyone. Comparing the system to reference photos in our guide on the radon mitigation system for a crawl space helps when the foundation is not a simple slab.
Reading the Manometer in Photos
The manometer is the single most useful component to learn, because it tells you whether the system works without any tools. The gauge holds colored liquid in a U-shaped tube. When the fan is pulling suction, the liquid sits at different heights in the two legs — one column higher than the other. When the legs are level, the fan has stopped or weakened and radon may be climbing back.
A careful installer marks the original reading on the gauge with a line or note, giving you a baseline to compare against. If you photograph your manometer periodically, you can track drift over time and catch a failing fan early. A changed reading is the prompt to retest radon and inspect the fan.
What to Do After Identifying Your System
Recognizing the parts is the start; verifying performance is what matters. Check the manometer for active suction, confirm the fan is running and outside living space, and look at the vent discharge location. Then retest radon to confirm the home is below the EPA action level of 4.0 pCi/L — appearance alone never proves a system is effective. The EPA recommends retesting every two years and after any system change.
Front Range homeowners have extra reason to verify rather than assume, since Colorado’s geology produces high radon and most local counties sit in the EPA’s highest radon zone. Our overview of high radon levels for Front Range homeowners explains why a healthy-looking system still needs a test behind it. If anything looks wrong in the pictures you take, a certified professional can diagnose and correct it.
Interior vs Exterior System Routing
Pictures of radon systems generally fall into two routing styles, and recognizing them helps you understand what you are looking at. In an interior-routed system, the PVC pipe runs up through the inside of the home — often through a closet, the garage, or a chase — into the attic, where the fan sits, before exiting through the roof. From outside, an interior system may show only a short pipe stub and a roof penetration, with the fan hidden in the attic. These installations are visually cleaner and protect the fan from weather, but they require interior space for the pipe run.
In an exterior-routed system, the pipe exits the foundation low on an outside wall and runs up the exterior of the house, with the fan mounted outdoors partway up and the pipe continuing above the eave. This is the configuration most people picture: a white pipe climbing the side of the house with a cylindrical fan in the middle. Exterior systems are easier to retrofit and inspect but expose the fan to the elements. Neither style is inherently superior; both are acceptable when installed correctly, and pictures simply reflect which approach suited the home. What matters in either case is correct fan placement, sealing, suction, and discharge location.
What a Correctly Placed Vent Discharge Looks Like
The vent discharge is one of the most important details to evaluate in any photo, because a poorly placed termination can let radon re-enter the home. Standard practice and EPA guidance call for the discharge point to be above the roof eave, a set distance above the roof surface, and a required horizontal distance away from windows, doors, and other openings — typically several feet — so the vented gas disperses into the atmosphere rather than drifting back inside.
In a good photo, the pipe terminates cleanly above the roofline with no nearby openings. Red flags include a discharge at or near ground level, a termination just below or beside a window, or a pipe that stops short of the roofline. These placement errors are surprisingly common in poorly executed retrofits and can undermine an otherwise functional system. Because the discharge is usually visible from the exterior, it is one of the easier components for a homeowner to assess from photographs, and a misplaced termination is a clear sign to have the system evaluated by a professional.
Recognizing a System That Has Failed
Photographs can also document failure, and knowing the signs lets a homeowner catch problems early. The clearest indicator is the manometer reading level — when the colored liquid sits at the same height in both legs of the U-tube, the fan has stopped or weakened and the system is no longer pulling suction. A photo of a level manometer is effectively a photo of a failed or failing system, and it should prompt an immediate radon retest and fan inspection.
Other visible failure signs include a fan that is silent or audibly grinding, a disconnected or cracked pipe, a sagging unsupported pipe run that traps condensation, or a fan that has been improperly relocated into a basement or other living space. Comparing current photos against the system’s original appearance — and against the manometer baseline a good installer marks on the gauge — makes drift and damage easy to spot. Periodically photographing your own system creates a visual record that turns vague impressions into documented evidence of how the system is performing over time.
Active and Passive Systems in Photos
Photographs can also help distinguish an active system from a passive one, a difference that affects how reliably a home is protected. An active system has a visible fan — the cylindrical housing spliced into the pipe — and shows a manometer with offset liquid levels indicating powered suction. A passive system, by contrast, has the same vertical pipe routed from the foundation up through the roof but no fan; it relies on natural convection, the stack effect, to draw soil gas upward without electricity.
In photos, the giveaway is the absence of a fan housing and often the absence of an electrical connection. Many newer homes are built with passive radon piping roughed in during construction, ready to be made active by adding a fan if testing shows elevated levels. Recognizing which type you have matters because passive systems are less reliable, especially in high-radon homes, since the natural draft varies with weather and season. If photos show a passive system in a region like the Front Range where radon runs high, that is a prompt to test the home and consider upgrading to an active system, which delivers the consistent, measurable suction needed to hold levels below the action level.
Using Photos as a Maintenance Tool
Beyond identification, photographs are a practical maintenance habit. Taking a clear picture of the manometer every few months and comparing the liquid levels lets a homeowner track suction over time and catch a gradually weakening fan before radon climbs. Photographing the fan, the pipe runs, and the discharge after installation creates a baseline reference that makes any later change — a new sag, a cracked coupling, a relocated fan — obvious at a glance.
For Front Range homeowners, this documentation habit pairs naturally with the EPA’s recommendation to retest radon every two years and after any system change. A photo log plus a testing routine is a low-effort way to keep an invisible-gas defense honest, since neither the gas nor a quiet fan failure announces itself. If photos reveal a misplaced fan, a level manometer, a questionable discharge, or physical damage, a certified mitigation professional can diagnose and correct the issue — but the photos are what alert you to look in the first place. Learning to read the system in a picture turns a confusing pipe into something you can monitor and trust, which is exactly the kind of informed vigilance that keeps a home protected from an invisible gas over the long run. For Front Range homeowners, where radon runs high and the margin is thin, that habit of looking and verifying is one of the simplest forms of protection available.
More Questions About Radon Mitigation Systems
How much does a radon mitigation system cost?
A radon mitigation system typically costs about $800 to $2,500 installed in a single-family home, according to industry estimates. Basement and slab homes with good sub-slab gravel are usually at the lower end. Crawl spaces needing a sealed membrane, homes with multiple foundations, interior routing through finished space and difficult soils push costs higher. The price normally includes the fan, piping, sealing major cracks and a manometer. Ask whether post-mitigation testing is included, and choose a certified radon mitigation professional.
How long does a radon fan last?
A radon fan typically lasts about 5 to 10 years or more, and many run longer when installed outdoors or in an attic with proper drainage. Fans run continuously, so bearings eventually wear out. Signs of failure include a manometer reading near zero, unusual noise, vibration, or a fan that is silent or not warm. Replacement fans commonly cost a few hundred dollars plus labor. Checking the manometer regularly and retesting radon catches a failing fan before levels rise for long.
Can a radon system use a sump pit?
Yes, a radon mitigation system can draw from a sump pit, and in many basements it is an effective suction point because the pit connects to drain tile around the foundation. The pit needs an airtight, sealed lid with a pipe connection, and the sump pump must remain serviceable. Some lids include a viewing port. An unsealed sump pit can also be a major radon entry point, so sealing it is often part of mitigation even when suction is placed elsewhere.
How much electricity does a radon fan use?
A typical radon fan uses roughly 50 to 150 watts and runs continuously, which commonly adds about $50 to $150 per year to electric bills depending on the fan and local rates. Higher-suction fans used for tight soils use more power. Operating costs are modest compared with the health goal of lowering radon. Choose a fan sized to the soil conditions instead of oversizing, which wastes energy and can pull more conditioned air out of the house.
References
- Consumer’s guide to radon reduction systems — EPA
- Colorado radon program and zone map — Colorado Department of Public Health and Environment
- Radon and lung health — American Lung Association
Frequently asked questions
How do I identify a radon mitigation system?
Look for a continuous white PVC pipe, usually 3 or 4 inches wide, running from a suction point in the lowest level up through the home or an exterior wall, through a cylindrical fan, and out above the roof, with a small manometer gauge on the pipe.
Where should the radon fan be located?
The fan must be outside the living space — outdoors, in an attic, or in a garage — never in a basement or occupied area, so any leak from the fan housing does not vent radon back into the home.
How can I tell if my radon system is working from a photo?
Check the manometer. If the colored liquid sits at different heights in the two legs, the fan is pulling suction. If the legs are level, the fan has stopped or weakened. A photo of the gauge over time helps you track drift.
Does a good-looking system mean radon is controlled?
No. Appearance never proves effectiveness. Retest radon to confirm the home is below the EPA action level of 4.0 pCi/L, and retest every two years and after any system change.
Should a radon fan run all the time?
Yes, a radon fan is designed to run continuously, 24 hours a day. Turning it off lets radon levels rise again, often within hours to days. The manometer and any alarm show whether the fan is working.
How often should radon be retested after mitigation?
Radon should be tested after a mitigation system is installed, then at least every two years, according to EPA guidance. Retest after major renovations, foundation changes or fan replacement, and anytime the manometer reading changes.
Does a radon mitigation system need a permit?
Some cities and counties require a permit for radon mitigation, especially for electrical work or exterior penetrations, while others do not. Requirements vary, so a certified mitigation contractor should confirm local rules and pull any needed permits.
If photos of your Front Range system show a misplaced fan, no suction, or a questionable vent, get in touch through our contact page to connect with a certified local mitigation professional.
Test your home for radon
Radon is invisible and odorless, so a test is the only way to know your level. A short-term kit gives a first reading in days; a digital monitor tracks it over time.
| Product | Why | Buy |
|---|---|---|
AirChek Charcoal Radon Test Kit | Lab fee usually included; EPA short-term protocol. | Amazon — $21.95 |
First Alert RD1 Radon Test Kit | Widely stocked; 48-hour charcoal test. | Amazon — $17.95 |
Airthings Corentium Home | Digital monitor with a long-term average. | Amazon — $99.99 |
AirChek Charcoal Radon Test Kit
First Alert RD1 Radon Test Kit
Airthings Corentium Home